Description
The Belden 4302UE New Generation Instrumentation Cable is a premium-quality, flame-retardant cable designed for high-accuracy signal transmission in advanced industrial and commercial control systems. Now available in Karachi, Pakistan, this cable is engineered to meet the demanding requirements of automation, process monitoring, and instrumentation applications across Pakistan’s industrial sectors.
This cable features 4 twisted pairs of stranded copper conductors (7×0.40B), providing superior flexibility, excellent signal stability, and reduced attenuation over long distances. The pair-balanced construction ensures accurate transmission of analog and digital signals, making it ideal for diverse process control and industrial communication tasks.
The FRNC (Flame Retardant Non-Corrosive) outer jacket significantly improves safety by reducing flame spread, limiting toxic gas emissions, and preventing corrosive byproducts during fire—critical for enclosed industrial facilities, commercial buildings, and sensitive installations throughout Karachi.
Belden 4302UE is widely adopted in PLC systems, DCS networks, SCADA applications, industrial sensors, instrumentation panels, and process control wiring, delivering excellent performance in electrically noisy environments due to its optimized design and high-quality insulation materials.
Whether wiring instrumentation loops in Korangi Industrial Area, setting up monitoring systems in Port Qasim, or integrating automation lines in SITE, engineers and integrators across Karachi, Pakistan trust the Belden 4302UE series for long-term stability, performance, and safety.
Key Features
4 twisted pairs of stranded copper conductors (7×0.40B)
FRNC jacket ensures flame retardance and low smoke toxicity
Stable signal transmission for analog and digital instrumentation
Durable insulation for long operational life
Excellent performance in industrial EMI conditions
Flexible design for easier installation in control panels
Suitable for process control, automation, and monitoring systems
Typical Applications in Karachi, Pakistan
Instrumentation and control wiring
PLC, DCS, and SCADA systems
Industrial sensors and measurement devices
Chemical, petrochemical, and manufacturing plants
Power plants, refineries, and industrial automation lines
Commercial buildings and BMS (Building Management Systems)
Data acquisition and process monitoring networks
Technical Specification Table
| Parameter | Specification (Typical for Belden 4302UE) |
|---|---|
| Cable Type | Multi-Pair Instrumentation Cable |
| Number of Pairs | 4 Pairs |
| Total Conductors | 8 Conductors |
| Conductor Material | Stranded Bare Copper |
| Conductor Size | 7×0.40 mm (approx. 20–21 AWG equivalent) |
| Insulation Material | Polyolefin / PE |
| Pair Shielding | Aluminum Polyester Foil (per pair) |
| Overall Shield | None (pair-shielded only) |
| Drain Wire | Yes (Tinned Copper) |
| Jacket Material | FRNC (Flame Retardant Non-Corrosive) |
| Jacket Color | Typically Blue or Grey |
| Nominal Outer Diameter | ~9.0–10.0 mm |
| Capacitance (Conductor-to-Conductor) | ~30–60 pF/m typical |
| Characteristic Impedance | ~100 Ω (typical for instrumentation) |
| Voltage Rating | 300V |
| Operating Temperature | –20°C to +90°C |
| Fire Performance | Low smoke, halogen-free, flame retardant |
| Standards Compliance | IEC 60332-1, IEC/EN instrumentation standards |
| Applications | Process control, Automation, SCADA, PLC, Sensors, Signal transmission |








Reviews
There are no reviews yet.